3 kvar 240V Power Factor Correction ES-1L

Celec is one of the leading manufacturers and exporters of 3 kvar 240V Power Factor Correction ES-1L, which aims to improve power quality issues including power factor and electrical harmonics.

Applicable Load6 – 9 kW
Power Rating2.8 kvar
Voltage Rating240V AC, 50Hz
Size12″ x 8″ (5″ depth)

SPECIFICATIONS

Order Code:  ES-1L
Applicable Load6 – 9 kW
Power Rating2.8 kvar
Voltage Rating240V AC, 50Hz
Full Load Current11.6 Amp.
Operating AmbientUpto 40°c
Steps6
Each Steps (kvar)0.1, 0.2, 0.4, (0.72 x 3)
Size12″ x 8″ ( 5″ depth )
Weight7 Kg (15 lbs)
TypeType-1, Wall Mounting

UL’s Listing Certified

UL-listed

Certificate Europe

Celec-Euro-Listing-Certificate

ISO 9001:2008 Certified

Celec TUV Certificate

Installation Manual

Description

Celec 3 kvar 240V Power Factor Correction ES-1L is Latest and high-efficiency electric power saving technology as well  it can provide effective protection for electricity appliances and Prolong their life span.

Celec Electricity Saver device has been our forte for Power Saving Solutions. We have Core Competence in the measurement and intelligent control of power factor even during power quality disturbances. So Electricity Saving box; which yields in low-carbon emission and power factor correction.

So Electricity saving Device understands power consumption and sets the capacitance saving level. Moreover; Its energy consumption monitor allows energy use to optimize in real time with a Bluetooth connection. This unit was designed for load fluctuations and maximizes in-phase energy. This intelligent monitoring increases potential energy savings at low and at peak energy demand levels. Electricity Saver can used in conjunction with renewable energy sources like Solar panels, Wind turbines and Inverters, etc.

Unique Features of  Power Factor Correction ES-1L

  • Digital Display of Power Saving
  • Power Monitoring of All Electrical Parameters
  • Easy Installation and Pluggable Current Sensors
  • Power logger indulgence against order

How 3 kvar 240V Power Factor Correction Works:- 

  • Power Factor Improvement
  • Reduced current on main line
  • Surge suppression for transient voltages
  • Filters input voltage from noise and impurity

Advantages of Power Factor Correction ES-1L

  • Reduction in Electricity Bills
  • Improvement in line voltage
  • Incentive on Electricity Bills in selected areas
  • Filter the voltage for longer life of equipment
  • Removal of power factor penalties demand charges

BENEFITS of Power Factor Correction ES-1L

  • Energy saving up to 30%
  • Complete home surge suppression
  • Reduced heat from appliances
  • Increased life of inductive motors including air conditioners, refrigerators, washers,HVACs systems and more
  • Increase the performance of renewable energy sources like Wind, Solar etc.

Title